Stirling Cooler SC-UERF, with Vacuum Flange
FPSC subLOGO

Main Feature

  • Applied to vacuum cooling use, adopting vacuum flange
  • Precise Temperature Control

    Stirling coolers can be operated full input range, such as 0 to 100%, this support your system to feature precise temperature control, with conventional controller.

  • Non-Freon System

    Stirling Coolers use Helium gas, Zero GWP (Global warming potential).

SC-UERF
Specifications

• Dimension

W180 x H169 x L431mm
Dimensional drawing (PDF)

• Weight

12Kg

• Power Source

DC48V (7.2A(RMS) 9A peak)

• Cooling Capacity

Min. 90W (-23.3C at cold side temp, ambient temp +25C)
Min. 15W (-100C at cold side temp, ambient temp +25C)

• Cooling Temperature Range

from -120C to +70C
(Operation Temp Range from 0C to +40C

• Noise Sound

55dB(A) (1m away from cooler horizontally)

• Accessory

Driver Board

*All values are typical data. Please confirm accurate value with approved Specification Sheet with each Customer.